A dedicated team is accessible for TorrentValid customers. One can reach our 24/7 customer support team to resolve their queries. Moreover, our team will also assist users if they face any kind of trouble while using above-mentioned formats of CDCS practice material. We will offer you a refund guarantee (terms and conditions apply) as saving your money is our priority. Additionally, we offer up to 1 year of free updates and free demo of the CDCS product. Order EXIN CDCS exam questions now and get excellent these offers.

EXIN CDCS Exam Syllabus Topics:

TopicDetails
Topic 1
  • Designing and Implementing a Data Centre: In this module, the exam assesses the knowledge of Exin data center professionals tasked with the design and implementation of data centers. Candidates will learn the key principles of creating an efficient data center layout, including considerations for scalability, redundancy, and security.
Topic 2
  • Data Centre Life Cycle and Standards: This section of the exam measures the skills of data center professionals and covers the various stages involved in the life cycle of a data center, from planning and design to implementation and decommissioning.
Topic 3
  • Data Centre Environmental Considerations and Efficiency: This section evaluates the proficiency of data center professionals in addressing environmental factors and promoting efficiency within data center operations. The target audience, including data center managers and engineers, will be tested on their ability to identify and implement measures that enhance energy efficiency, cooling management, and sustainable practices.

>> Excellect CDCS Pass Rate <<

Features that Make TorrentValid's EXIN CDCS Questions Top Choice for Exam Preparation

You can see the recruitment on the Internet, and the requirements for CDCS certification are getting higher and higher. As the old saying goes, skills will never be burden. So for us, with one more certification, we will have one more bargaining chip in the future. However, it is difficult for many people to get a CDCS Certification, but we are here to offer you help. We have helped tens of thousands of our customers achieve their certification with our excellent CDCS exam braindumps.

EXIN EPI Certified Data Centre Specialist Sample Questions (Q30-Q35):

NEW QUESTION # 30
The data center has been in operation for about 1 year and 2 months. The dust levels in the computer room are relatively high.
What is the most likely root cause?

  • A. Every computer room has high dust levels due to constant high-speed air movement
  • B. Low pressure in the computer room
  • C. Floorboards are most likely not fitted correctly
  • D. The cleaning crew is not doing their work properly

Answer: C

Explanation:
High dust levels in a computer room are often due to improperly fitted floorboards. When floorboards are not securely installed or do not fit tightly, they allow dust and particles from the subfloor to enter the room. In a data center, this can lead to high levels of dust that affect air quality and equipment performance.
Detailed Explanation:
Raised floors in data centers can accumulate dust and debris, especially if the floorboards are not properly sealed. Loose or improperly fitted floorboards allow contaminants from the subfloor to enter the data center environment, increasing the dust levels over time. Proper installation and maintenance of floor panels are essential to prevent dust infiltration and maintain clean conditions.
EPI Data Center Specialist References:
EPI training emphasizes proper flooring installation and maintenance to control air quality within data centers. Correctly fitted floorboards prevent dust accumulation from the subfloor, which helps protect sensitive equipment and maintains a cleaner environment.


NEW QUESTION # 31
You are changing the design of the fire suppression system for your computer room from a halocarbon fire suppression system into an inert-based fire suppression system. Could you use the same formula to calculate the gas content for the gas?

  • A. No, there is a significant difference in the formula for the different types of fire suppression gases.
  • B. Yes, as long as you take the difference between the net and gross volume into account.
  • C. Yes, as long as you change the 'S' factor of the formula to reflect the gas type used.
  • D. Yes, as long as you use the same units of measure, i.e., kg/m³ or lbs/ft³.

Answer: A

Explanation:
The formula used to calculate the gas content differs significantly between halocarbon and inert-based fire suppression systems. Halocarbon systems function by absorbing heat, while inert systems work by reducing oxygen levels. Due to these differences in fire suppression mechanisms, distinct formulas are applied, factoring in the specific properties of each gas type and the required concentration levels.
Detailed Explanation:
Halocarbon systems like FM200 require a formula that accounts for the concentration needed for cooling, while inert gases like nitrogen or argon need a formula that calculates the volume based on oxygen displacement. As the design concentration and characteristics of these gases differ, it's essential to use the correct formula specific to the gas type.
EPI Data Center Specialist References:
EPI recommends consulting the specific design requirements and formulas provided by each gas manufacturer when switching fire suppression systems to ensure the correct amount of gas is deployed for effective fire suppression.


NEW QUESTION # 32
You are allowed to use a calculator for this question. A battery bank is rated at a total capacity of 600 Ah. Calculate how much charging current the rectifier should be able to supply as charging current.

  • A. 60 Amperes
  • B. 80 Amperes
  • C. 30 Amperes
  • D. 12 Amperes

Answer: C

Explanation:
To determine the charging current for a battery bank, a general rule of thumb is that the charging current should be 5% of the total battery capacity. For a battery rated at 600 Ah, this calculation would be:
600 Ah×0.05=30 Amperes600 , text{Ah} times 0.05 = 30 , text{Amperes}600Ah×0.05=30Amperes This ensures the battery is charged efficiently without overloading the rectifier or risking battery damage.
Detailed Explanation:
Battery charging current is typically set as a percentage of the battery's capacity to balance effective charging with longevity and safety. A 5% charging rate is standard for lead-acid batteries, which would be 30 Amperes for a 600 Ah battery bank.
EPI Data Center Specialist References:
EPI standards recommend calculating charging currents based on a percentage of the battery capacity to ensure safety and efficiency, aligning with best practices for battery management in data centers.


NEW QUESTION # 33
What should be considered when installing overhead data cabling?

  • A. Optical fiber cabling should always be positioned on top of the copper cabling in the same cable tray to avoid damage to the sensitive optical fiber.
  • B. Copper data cabling should not be placed in metal cable trays.
  • C. All cabling should make sharp bends directly into the rack to avoid usage of additional space and blocking the airflow on top of the rack.
  • D. To maintain minimum separation from power and ensure that the fire detection and suppression systems are not hindered.

Answer: D

Explanation:
When installing overhead data cabling, it's crucial to maintain minimum separation from power cables to prevent electromagnetic interference. Additionally, cabling should be arranged so that it does not obstruct fire detection and suppression systems, allowing for proper sensor function and suppression agent dispersion in the event of a fire.
Detailed Explanation:
Separation between power and data cabling minimizes the risk of interference and helps ensure compliance with standards for signal integrity. Proper placement relative to fire suppression systems ensures that any smoke or heat can be effectively detected, and suppression agents can be evenly distributed without obstruction from cabling.
EPI Data Center Specialist References:
EPI guidelines emphasize maintaining adequate separation between power and data cables for safety and performance and ensuring cabling does not interfere with essential safety systems in data centers.


NEW QUESTION # 34
From the options indicated, what is the correct starting point for the raised floor installation?

  • A. Point B
  • B. Point C
  • C. Point D
  • D. Point A

Answer: A

Explanation:
When installing a raised floor, the best starting point is typically from the farthest corner away from the entrance, in this case, Point B. This method allows for the floor installation to progress towards the entrance, ensuring that workers can avoid walking over the newly installed tiles, thus minimizing the risk of damage and maintaining cleanliness during installation.
Detailed Explanation:
Starting at the farthest corner (Point B) and working towards the entrance (Point A) is a standard practice in raised floor installation. This approach ensures that installers do not walk over freshly laid tiles, which could lead to shifting or misalignment. Additionally, it allows for more controlled placement and alignment, as well as convenient egress when installation is complete.
EPI Data Center Specialist References:
EPI guidelines for raised floor installation emphasize beginning at the farthest point from the entrance and working back towards it, which aligns with industry best practices for efficiency and quality assurance. This method reduces potential damage and supports precise alignment across the floor area.


NEW QUESTION # 35
......

The EXIN Questions PDF format can be printed which means you can do a paper study. You can also use the EXIN CDCS PDF questions format via smartphones, tablets, and laptops. You can access this EXIN CDCS PDF file in libraries and classrooms in your free time so you can prepare for the EXIN EPI Certified Data Centre Specialist (CDCS) certification exam without wasting your time.

Valid Dumps CDCS Ppt: https://www.torrentvalid.com/CDCS-valid-braindumps-torrent.html